RAID 0+1 Calculations

To calculate the number of drives necessary to meet the storage requirements with RAID 0+1, divide the Total Storage Requirements by the Drive Size Actual. Round the result up and multiply by 2. For this example, 10 drives are needed for RAID 0+1 to meet the storage requirements:

10 = ROUNDUP(540÷132)*2

To calculate the number of drives required to meet the performance requirements with RAID 0+1, multiply the Number of Write IOPS by 2 and add the Number of Read IOPS. Divide this total by the Calculated Drive IOPS and round the result up. For this example, 4 drives are needed for RAID 0+1 to meet the performance requirements:

4 = ROUNDUP(((140*2)+140)÷125)

Although RAID 0+1 can meet the performance requirements with just ...