RTA000141603

 Item RTA000141603 Source..........: PDDB0 PDDB0 Last updated....: 09/26/2000 Abstract........: Rebuild of IGWLOCK00 stalled after loss of coupling facility. USERS: VSAM PROBLEM SUMMARY: Rebuild of IGWLOCK00 stalled after loss of coupling facility. SMSVSAM unable to re-INIT on all systems. SOLUTION: Issue V SMS,SMSVSAM,FORCEDELETELOCKSTRUCTURE comand. PROBLEM DETAILS: TYPE: WAD COMPID: 5695DF122 RELEASE: 1D0 CUSTOMER: Lost the CF on which the IGWLOCK00 structure resided. While the structure was being rebuilt, also lost the SMSVSAM server on N7B. This caused all the other SMSVSAM servers to kill themselves (as expected). However, once they restarted, the rebuild of IGWLOCK00 was either stalled or stopped. In any event, the structure ...