Chapter 10.3.1. Queue depths

Page 182

182 SAN Volume Controller: Best Practices and Performance Guidelines 1 Scsi Port2 Bus0/ Disk2 Part0 OPEN NORMAL 1863138 0 2 Scsi Port3 Bus0/ Disk2 Part0 OPEN NORMAL 0 0 3 Scsi Port3 Bus0/ Disk2 Part0 OPEN NORMAL 1839632 0 To change the I/ O Group, you must first flush the cache within the nodes in the current I/ O Group to ensure that all data is written to disk. The SVC command line interface ( CLI) guide recommends that you suspend I/ O operations at the host level. The recommended way to quiesce the I/ O is to take the volume groups offline, remove the saved configuration ( AIX ODM) entries, such as HDisks and vpaths for those that are planned for removal, and then gracefully shut down the hosts. Migrate ...

Get SAN Volume Controller: Best Practices and Performance Guidelines now with the O’Reilly learning platform.