152 PDA Management with IBM Tivoli Configuration Manager
6. Once the PocketPC device is performing a synchronization operation, the job
gets scheduled, and the inventory scan starts to run. Figure 4-58 shows this
sequence.
Figure 4-58 Inventory scan -being scheduled and performed
7. Alternatively, you can verify the $DBDIR/mcollect/mcollect.log for the success
of the inventory scan:
Example 4-9 mcollect.log successful inventory scan
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] debug_level:1
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] depot_location:depot
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] depot_size:41943040
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] depot_chunk:1048576
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] thread_idle_down_time:60
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] thread_sleep_time:5
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] max_input_threads:5
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] max_input_retries:10
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] max_output_threads:5
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] retry_delay_time:1
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] router_cache_lines:0
Mar 14 11:47:14 1 [pid:00017102 tid:536928744]
temp_dir:/tivoli/db/itcmpda5.db/mcollect
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] depot_load - begin loading index
cache.
Mar 14 11:47:14 1 [pid:00017102 tid:536928744] depot_load - end loading depot
index cache.
8. We execute the WINCE_FILE_QUERY from the Tivoli Desktop to verify the
installation of the Adobe Acrobat Reader on the PocketPC device and if the