The Minimum Flow Control Advertisement

The minimum number of credits that can be reported for the different Flow Control buffer types is listed in Table 7-1 on page 303.

Table 7-1. Required Minimum Flow Control Advertisements
Credit TypeMinimum Advertisement
Posted Request Header (PH)1 unit. Credit Value = one 4DW HDR + Digest = 5DW.
Posted Request Data (PD)Largest possible setting of the Max_Payload_Size; for the component divided by FC Unit Size (4DW). Example: If the largest Max_Payload_Size value supported is 1024 bytes, the smallest permitted initial credit value would be 040h.
Non-Posted Request HDR (NPH)1 unit. Credit Value = one 4 DW HDR + Digest = 5DW.
Non-Posted Request Data (NPD)1 unit. Credit Value = 4DW.
Completion HDR (CPLH)1 unit. Credit ...